This OSHA Injury Report was compiled directly from data that is publicly available from the Occupational Safety and Health Administration (OSHA). OSHA Injury Reports can be helpful in understanding the types of workplace injury claims involving defective products or malfunctioning equipment in the workplace. 

The manufacturers of defective equipment or machinery resulting in a worker injury may be found to be negligent and liable for damages in a separate civil lawsuit. You may be able to recover damages on top of a workers’ comp claim if injured in a job accident caused, in part, by a third party. These third party personal injury cases should be given responsible legal guidance.

Trammell Piazza Law Firm claims no responsibility for any errors or inconsistencies in OSHA’s data.

A link is provided below to share or embed this report.

Report: Contact with hot objects or substances at Lion Elastomers in Port Neches, Texas

DATE: 08/09/15

An employee was taking off the access panel of the E Line Coagulation Tank to clean the excess solids out of it. As the employee was doing that the residuals (adjusted pH hot water 150-160 degrees Fahrenheit, liquid latex, and 93% sulfuric acid) splashed onto the employee. The pH of the residuals was approximately 3.2. The employee received second degree burns down the right side of his body. The employee was hospitalized.

Report ID 2015085586  
Date 08/09/2015  
UPA 1008855  
Primary NAICS 325211  
Nature 1592 Other burns, second degree
Part of Body 80 Multiple body parts, unspecified
Source 9521 Water
Secondary Source 1115 Sulfuric acid
Event 533 Contact with hot objects or substances
Hospitalized Yes  
Amputation No  